Quick answer: two sums do it. Height of instrument = benchmark elevation + rod reading on the benchmark. Then, at any point, rod reading = height of instrument − invert elevation. As the pipe falls, the rod reading gets larger. Work out the reading for each station before you dig, and lay the pipe to those numbers.

A rotating laser gives you one flat plane of light. It does not know your slope; the slope is in the list of rod readings you carry down the trench. Get that list right once and every length of pipe has a target.

The terms

A worked example

Benchmark at 100.00 ft. The rod on the benchmark reads 4.25 ft, so the height of instrument is 104.25 ft. The drain starts at invert 98.00 ft and runs 60 feet at ¼ inch per foot, which is 5 inches (0.417 ft) of drop every 20 feet.

StationDistanceInvertRod reading
Start0 ft98.00 ft6.25 ft
120 ft97.58 ft6.67 ft
240 ft97.17 ft7.08 ft
360 ft96.75 ft7.50 ft

The last line checks itself: 60 feet at ¼ inch per foot is 15 inches, or 1.25 ft, and 98.00 − 1.25 = 96.75.

Where the rod sits

The readings above are to the invert. If you set the rod on top of the pipe, the reading is smaller by the pipe's inside diameter plus one wall thickness. If you check the trench bottom before bedding, it is larger by the bedding depth plus the wall thickness. Pick one, apply the same offset at every station, and say which one on your notes.

Two readings give you the slope

The sum works backward too. Two rod readings on the same setup, subtracted, give the drop between those points. Readings of 6.25 ft and 6.67 ft, 20 feet apart, are 0.42 ft or 5 inches of drop: ¼ inch per foot.

Let the app carry the list

  1. In Pipe Slope Calculator, open a run and enter its segments and start invert.
  2. Under Laser Readings, enter the benchmark elevation and the rod reading on it. The app shows the height of instrument.
  3. The station table gains a Rod column: the reading to expect at every station, updated when you change a slope or a length.
  4. In Find Slope, enter two rod readings instead of a drop and the app works out the slope and checks it.

A pipe laser is different

A pipe laser sits in the trench and shoots a beam down the pipe at a grade you dial in, usually as a percent. For ¼ inch per foot, that is 2.08%; for ⅛ inch per foot, 1.04%. The set-out numbers in the app give the percent to dial in for any slope.

Reference only: a bumped tripod changes every reading. Re-check the rod on the benchmark whenever the laser may have moved, and confirm final grades and elevations against your drawings and local authority.

Related questions

What is height of instrument?

The elevation of the laser plane. It is the benchmark elevation plus the rod reading taken on that benchmark.

Why does the rod reading get bigger as the pipe goes down?

The rod measures from its foot up to the laser. A lower point is farther below the laser, so the reading is larger.

How do I find the slope from two rod readings?

Subtract one reading from the other to get the drop, then divide by the distance between the two points. A 0.42 ft difference over 20 feet is ¼ inch per foot.

What grade do I set on a pipe laser for ¼ inch per foot?

2.08%. For ⅛ inch per foot, set 1.04%.

The rod reading at every station

Enter a benchmark once and see the rod reading for each invert of a run. Offline, on iPhone and iPad.