Quick answer: most French drains and yard storm lines are laid at about 1%, which is ⅛ inch per foot or roughly 1 inch every 8 feet. Many installers aim for 1% to 2% where the ground allows it. Unlike a sanitary drain, there is usually no single plumbing-code minimum for these lines: the number comes from the designer, the pipe maker or your local authority.

Search for this and you will find ⅛ inch per foot, 1%, 2% and "it depends" on the same page of results. They are all describing the same idea from different angles. Here is how to pick a number, what it means in inches over your run, and how to check the pipe against it.

Why there is no single code number

The minimum-slope tables in the IPC, UPC and NPC are written for sanitary drainage: pipes that carry solids and need a scouring flow. A perforated French drain, a downspout line or a yard catch-basin line carries clear water, and is often outside that table altogether. Storm piping that is inside a plumbing code's scope is sized from its own tables, where the slope you choose sets how much water the pipe can carry.

So the practical sources for your number are, in order: a drawing or grade slip if you have one, the local authority if the work is permitted, the pipe or system manufacturer, and only then a rule of thumb.

The common rules of thumb

How much drop is that over your run?

Run lengthDrop at 1%Drop at 2%
10 ft1¼ in2⅜ in
25 ft3 in6 in
50 ft6 in12 in
75 ft9 in18 in
100 ft12 in24 in

Check this against the site before you dig. A 100-foot line at 1% needs the outlet a full foot lower than the start, plus the depth of the trench at the high end. If the outlet cannot be that low, a shorter run, a different outlet or a dry well is a better fix than a flatter pipe.

Checking a slope against your own target

  1. In Pipe Slope Calculator, choose Custom beside IPC, UPC and NPC.
  2. Enter your minimum, for example 1%, and a maximum if your drawing gives one. You can type it as a percent, a ratio, in/ft or mm/m.
  3. Enter the run length and either the slope or the drop. The result tells you whether it meets your target and by how much it is over or under.

The app labels this as your target, not a code check, because that is what it is: a number you chose, checked consistently on every calculation, run and report.

Reference only: the figures on this page are common practice, not a code requirement. Drainage that connects to a building, a municipal system or a neighbour's property is often regulated. Confirm the required slope and outlet with your local authority or designer.

Related questions

What is the minimum slope for a French drain?

There is no universal minimum. About 1% (⅛ inch per foot) is the usual rule of thumb for 4-inch perforated pipe, and many installers use 1% to 2%. A drawing, the pipe maker or your local authority may set a different figure.

Can a French drain be level?

A level pipe still drains slowly through its perforations, but any low spot holds water and collects silt. A steady fall toward the outlet is the safer choice.

Is storm drain slope the same as sewer slope?

Not necessarily. The plumbing codes' minimum-slope tables are written for sanitary drains. Storm piping is sized from separate tables, and yard drainage is often outside the plumbing code.

Can a drain pipe have too much slope?

For clear-water drainage a steep pipe mainly raises the risk of erosion at the outlet. For sanitary drains the question is different; see the guide on maximum slope.

Check any slope against your own target

Set a minimum and maximum of your own, then check every run against it. Offline, on iPhone and iPad.